    P9000M  Multi-Para Patient monitor

     

    Features &Benefits:

    5 standard parameters: ECG, RESP, NIBP, SPO2, 1-TEMP.

    Real time S-T segment analysis, pace-maker detection and ARR analysis.

    Multi-display selectable including standard, large font, trend coexis, OxyCRG dynamic

    On-line help and Patient info input management

    Multi-lead ECG waveforms display in phase.

    Large volume of tabular and graphic trends information storage and easy to recall

    Capture dynamic waveforms.

    Efficient resistance to interference of defibrillator and HF knife.

    Up to 4 hours working capacity of built-in rechargeable battery.

    Networking capacity and TCP/IP networking platform.

     

    Option of FHR,FM,TOCO,Printer , IBP and EtCO2

     

     

    Performance Specifications

    Rolling and refreshing waveform display

    Multi display selectable including:

    Large-font display

    Trend coexist display

    OxyCRG dynamic view display.

    Bed-to-bed view display

    Trace:        9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

    Sweep speed:12.5mm/s,25mm/s,50mm/s

    Indicator:      Power/battery indicator light

    QRS beep and alarm sound

    Battery:       Rechargeable lead acid cell, 12v/4AH

    Max.24 hour for charging, 4 hours for continue working

    Trend:        Parameter graphic and tabular trends:

    5s/piece,8 hours;

    1min/piece,168 hours(24hour×7days)

    5min/piece,1000 hours.

     

    Storage:       NIBP:1000 groups

    Alarm:200 groups

    Full disclosure waveforms:1 hour

    Alarm:        User-adjustable High, Medium and Low limits 3-level Audible and visual alarm

    Networking:   Connected to central monitoring system

    TCP/IP netting platform

     

    Standard Parameters

     

    ECG:

    Lead mode:                               5 –lead(R,L,F,N,C)

    Lead selection :                        I,II,III,avR,avL,avF,V

    Waveform:                          3 and 7 channel selectable

    Gain selection:                        0.5mm/mv,1mm/mv,2mm/mv

    Sweep speed:                         12.5mm/s;25mm/s;50mm/s

    Heart rate range:                       

    Adult: 15~300bpm;

    Neonate:/pediatric:15~350bpm

    Accuracy: +1bpm or +1%,whichecer is greater

    Resolution:1bpm

    Filter: surgery mode:1~20Hz

    monitor model:0.5~40Hz

    Diagnostic mode:0.05~130Hz

    Scaling signal: 1mv,+3%

    Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

    Alarm range:15~350bpm

    S-T segment detecton:                  

    Measurement range:  2.0mV~+2.0mV                         

     

     Alarm Range:         -2.0mV~ +2.0mV

    Accuracy:            -0.8mV ~+0.8Mv

    Error:               +0.02Mv

     

    Arrhythmia analysis:      YES

     

    SPO2

    Measurement range:        0~100%

    Resolution:                1%

    Accuracy:                 +2%(70-100%);0-69% unspecified

    Alarm range               0~100%

    Pluse Rate:                range:20~300bpm

    Resolution:1bpm

    Error:+1bpm or +2%,whichever is greater

     

    NIBP

    Method:   Digital Automatic oscillometric

    Operation mode :  Manual/Automatic/continuous

    Auto measurement time:     Adjustable(1~480min)

    Measurement Unit:   mmHg/Kpa selectable

    Measurement types:  Systolic, Diastolic, Mean 

    Measurement tange:

    Range of Systolic pressure:  

    Adult: 40~270mmHg

    Pediatric: 40~220mmHg

    Neonate: 40~135mmHg

    Range of mean pressure:    

    Adult: 20~235mmHg

    Pediatric: 20~165mmHg

    Neonate: 20~110mmHg

    Range of diastolic pressure:  

    Adult: 10~215mmHg

    Pediatric: 10~150mmHg

    Neonate :10~100mmHg

    Over-pressure protection:    

    Double safety protection

    Resolution:  1 mmHg

    Alarm:      Systolic.Diastolic,Mean

     

     

    RESPIRATION

    Method:                     Thoracic impedance

    Measurement range:           Adult:7~120rpm;

    Neonate/Pediatric:7~150rpm

    Apnea alarm:                 YES,10~40s

    Resolution:                   1rpm

    Accuracy:                    +2rpm

     

     

    TEMPERATURE

    Compatible probe:             YSI or CYF

    Measurement range:           5~50℃

    Resolution :                   0.1℃

    Accuracy:                    +0.1℃

    Refreshing time:               about 1

    Average measuring time:        <10s

     

     

    FHR

    Transducer:   Multi-crystal, Pulsed Doppler

    Measurement range:  50~210 BPM

    Working frequency:   1 MHz

    Strength:   <5mW/cm2

    Signal processing: 

    special DSP system and modern recognization.

    Resolution:   1BPM

    Accuracy:    ±1BPM

    Alarm Range:  High: 160,170,180,190 BPM,

    Low: 100,110,120 BPM

     

    FM

    Manual button marking,

    automatic FM identifying function

     

    TOCO Measuring

    Transducer:  External pressure transducer

    Measurement range:  0~100 units

    Resolution:  1rpm

    Accuracy:  ±2 rpm

     

     

    IBP

    Channel: 2 channels

    Range: -50-300mmHg

    Resolution: 1mmHg

    Accuracy: ±4mmHg(±4%)

    Unit: mmHg, Kpa

    Converter Sensitivity: 5mV/V/mmHg

    Transducer sites: ART/PA/CVP/LAP/RAP/ICP

     

     

    EtCO2Sidertream CO2)

    Measurement range:   0~99mmHg

    Accuracy:   +2mmHg (0~40mmHg)

    Sampling Range:   100ml/min

    Sampling rate accuracy:   15%

    Respiration rate:   0~120rmp

    Respiration accuracy:  +2rmp (0~70rmp)

    +5rmp (>70rmp)

    Respiration time:   <240msec (10% to 90%)

    Delay time:  <2s

     

    EtCO2 (mainstreaam CO2)

    Method:   Infrared Spectrum

    Range:   0.0-10% (0~76%)

    Resolution:   1mmHg (0.1%)

    Accuracy:   <5%(±4.0 mmHg)

             Or<10%(of Readings)

     

    Recorder:     

    Build-in, thermal array

    Plethysmogram caveform:3 channels

    Record mode: manual, on alarm, time-defined

    Recording width: 50mm

    Printing speed: 50mm/s

    Recording type:  Frozen waveform record

    NIBP recall record

    Trend table record

    Alarm record

    Fixed -time record

     

     

    Miscellaneous

    Satety:              

    Safety level: Class I, type CF

     

    Dimendion and Weight

    Dimendion:      440×430×450         

    G.Weight:        <9.0KS

     

    Operation Environment

    Temperature:    Working 0~+40℃

    Transportation and storage –20~+60℃

    Humidity:    working≤85%

    Transportation and storage≤93%

    Power:    AC 100-240,50/60Hz

    Patient range:   

    Neonate, pediatric, and adult patients

     

     

    Standard Accessories:

    (1) 5 lead ECG cable 

    (2) 1 spo2 probes 

    (3) 1 NIBP prbe 

    (4) 1 temp probe

    (5)1 ground connecting liner 

    (6) Chest electrode (10pcs/set)